Model 4214 In-line Ultra-clean Nitrogen Ionizer

ファイルをダウンロード 製品のお問い合わせ

Specifications:

4214
 Input Voltage  +24 VDC ± 5%, 0.25 A, 6W (typ)
 Decay Time  < 10 s @ (1000 V to 100 V, 15.2 cm,
 N2 flow 0.04m3/min @ 0.365 bar)
 Balance  <± 25 V @ (15.2 cm, N2 flow 0.04 m3/min @ 0.365 bar)
 Technology  High Frequency AC Ionization
 Cleanroom Class  ISO 14644-1 Class 1 (0.1 µm particles);
 ISO 14644-12 (0.01 µm particles)
 Gas Input  Nitrogen, minimum purity 99.999%
 Gas Consumption  (0.040m3/min @ 0.365 bar) to (100 m3/min @ 1.97 bar)
 Operating Env.  15 - 60ºC
 Filter Cartridge  Disposable, 99.999% for 0.01 micron
 Enclosure  Stainless Steel
 Dimensions  15.2L x 7.3W x 3.2H cm
 Weight  0.64 kg
 Certifications   



Easy Tool Integration:

  
Model 4214 is a stand-alone unit providing a high voltage power supply, an ultra-clean ionization cell, and I/O connections for remote status and control. Nitrogen is plumbed through where it is ionized and then delivered to the target area.