Specifications:
4214 | |
Input Voltage | +24 VDC ± 5%, 0.25 A, 6W (typ) |
Decay Time | < 10 s @ (1000 V to 100 V, 15.2 cm, N2 flow 0.04m3/min @ 0.365 bar) |
Balance | <± 25 V @ (15.2 cm, N2 flow 0.04 m3/min @ 0.365 bar) |
Technology | High Frequency AC Ionization |
Cleanroom Class | ISO 14644-1 Class 1 (0.1 µm particles); ISO 14644-12 (0.01 µm particles) |
Gas Input | Nitrogen, minimum purity 99.999% |
Gas Consumption | (0.040m3/min @ 0.365 bar) to (100 m3/min @ 1.97 bar) |
Operating Env. | 15 - 60ºC |
Filter Cartridge | Disposable, 99.999% for 0.01 micron |
Enclosure | Stainless Steel |
Dimensions | 15.2L x 7.3W x 3.2H cm |
Weight | 0.64 kg |
Certifications |
Easy Tool Integration:
Model 4214 is a stand-alone unit providing a high voltage power supply, an ultra-clean ionization cell, and I/O connections for remote status and control. Nitrogen is plumbed through where it is ionized and then delivered to the target area.