Extreme Temperature Ionization System

下載文件 產品查詢

Simco-Ion’s new Extreme Temperature Ionization System provides <±5V balance in extreme environments from -50°C to +155°C. The 4612 Ionizer, along with its 4062e-CLC Controller and 550 Extreme Temperature Antenna use closed-loop control to ensure the ionizer’s output is balanced at the location that’s critical—the product location itself.

The compact size of the 4612 Precision Ionizer, 4062e Controller and 550 Antenna are the perfect answer to maintain tightly-controlled ionization in small test chambers with active robotics moving parts under extreme environments. The 4612 Precision Ionizer uses high voltage DC technology along with tungsten emitters so it can be used in ISO 14661-1 Class 6 cleanliness environments.

Features:

  • Operates in temperatures as high as 150°C (310°F) and as low as -50°C (-58°F).
  • Balance control of better than ±10V standard meets the new stringent requirements for S20.20.
  • 550 Antenna to measure balance at the device location.
  • Optional feedback control using Novx Active Antenna with the Model 3362


Benefits:

  • Eliminates static charge in extreme environments that cannot sustain any other static elimination method
  • Self-balancing ionization eliminates calibration in the tight confines of the test chamber
  • Ensures that balance is maintained at the target where it matters, not just at the ionizer itself
  • Eliminates the need for two antennas for process monitoring 


Specifications:

Ionizer Model 4612
 Input Voltage  +24 VDC, ± 5% @ 0.25 A, 6W (max)
 Balance  ±10V (typ) around initial set point
 Discharge1  10 sec (depending on environment)@ 12" (300 mm) with 100 fpm gas velocity (decay time for ± 1000-100V)
 Ion Emission  DC corona discharge
 Cleanliness  ISO 14644-1 Class 6
 Ion Emitter  Tungsten
 Gas  Clean dry air or Nitrogen with minimum purity 99.99%
 Gas Velocity  100 fpm (min) velocity past 4612 Ionizer
 Gas Supply Temp  150ºC (max)
 Operating Temp  -50ºC to + 150ºC (max)
 Alarms  Low input voltage; HV output fault; antenna signal too variable/noisy and/or out of range
 FMS  Relay contact, rated ±24 VDC @ 0.2A, max 4-20 mA Current output
 Mounting  4612-210 Ionizer: (2) M4 holes, 4612-526 Ionizer: (4) M4 holes
 Enclosure  4612 Ionizer: PEEK; 550 Antenna: PTFE and Stainless Steel
 Dimensions  4612-210 mm Ionizer: 8.3"L x 0.8"W x 1.2"H (210 x 21 x 30 mm)
 4612-500 mm Ionizer: 20.7"L x 0.8"W x 1.2"H (526 x 21 x 30 mm)
 550 Antenna: 1.7 dia x 0.9"H (44 dia x 22 mm)
 Weight  4612-210 mm Ionizer: 365 grams (12oz)
 4612-500 mm Ionizer: 515 grams (18oz)
 550 Antenna: 0.3 lbs (0.14 kg) including cables
 Certifications  


Controller Model 4062e
 Input Voltage  24 VDC ± 5% @ 1.0A to 4062 Controller (optional external power supply to convert from 100-240 VAC to 24   VDC)
 Output   Voltage  ±6.5 kV max, peak-to-peak
 Operating Env  10-35ºC (50-95ºF); 30-60% RH, non-condensing
 Controls  Balance adjust
 LED Indicators  Green POWER, red ALARM (indicates instability or HV power failure)
 Connections  RJ-11 connector for 24 VDC input; two HV connectors; RJ-9 connector for FMS output (relay closure & 4-20 mA); SMA connector for antenna
 Mounting  (2) M4 holes
 Enclosure  Stainless steel
 Dimensions  201L x 92W x 57H mm (7.9L x 3.6W x 2.2H in)
 Weight  1.1 kg (2.4 lb)
 Warranty  Two-year limited warranty (4612 ionizer and 4062e controller)
 Certifications  
1. Tested in accordance with ANSI/ESD STM3.1-2015.


  


Ionizer Balance Control
The 4062e Controller, when paired with the 550 Antenna and 4612 Precision Ionizer, will provide balance to within ±10V, following industry-standard ANSI/ESD STM3.1-2006 protocols in a steady-state environment. Changes in temperature, humidity, air composition, and/or moving mechanical components in the area will temporarily impact balance. The use of the 550 Remote Antenna and closed-loop control provide the fastest, most accurate corrections for such changes.


Balance Control & Decay Test Option
The standard Novx 3362 with its standard antenna’s, can replace the 550 Antenna to monitor and control the extreme temperature. Using the Novx 3362 with the feedback control kit, will allow active feedback and control.


 Compact Controller
The 4062e Controller is a physically small unit, to allow it to be mounted almost anywhere inside a tool within a few meters of the Precision Ionizer itself.
 



Ordering Information

 91-4062e-01  4062e Controller
 91-4612-210-01  4612-210 Ionizer with 4m cable
 91-4612-210-6-01  4612-210 Ionizer with 6m cable
 91-4612-526-01  4612-526 Ionizer with 4m cable
 91-4612-526-6-01  4612-526 Ionizer with 6m cable
 33-0550-4M-01  550 Antenna
 33-1920-01  Tungsten emitter wires replacement (9)
 33-1921-01  Tungsten emitter wires replacement (21)
 33-2462-01  Novx 3362 to 4062e feedback control kit
 33-5701-1  24 VDC Power Supply
 25-20750  China Power Cord
 25-20735  Europe Power Cord
 25-20660  Nothern America Power Cord
 25-20710  UK Power Cord